product_image_name-Schneider- 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 220 to 230VAC coil Contactor, TeSys K-1

Share this product

Schneider 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 220 to 230VAC coil Contactor, TeSys K

₦ 29,095
₦ 33,09512%

1 units left

+ shipping from ₦ 750 to LEKKI-AJAH (SANGOTEDO)
0 out of 5
(No ratings available)
Variation available

Promotions

Delivery & Returns

Choose your location

Pickup Station

Delivery Fees ₦ 750
Ready for pickup between 25 February and 26 February if you place your order within the next 7hrs 56mins

Door Delivery

Delivery Fees ₦ 1,710
Ready for delivery between 25 February and 26 February if you place your order within the next 7hrs 56mins

Return Policy

Free return within 7 days for ALL eligible itemsDetails

Seller Information

Jet Gate Nigeria Ltd

96%Seller Score

3 Followers

Follow

Seller Performance

Shipping speed: Good

Quality Score: Excellent

Product details

RangeTeSys
Product or Component TypeContactor
Device ApplicationControl
Contactor applicationMotor control
Resistive load
Utilisation categoryAC-3
AC-3e
AC-1
AC-4
Poles description3P
power pole contact composition3 NO
[Ue] rated operational voltagePower circuit <= 690 V AC <= 400 Hz
Signalling circuit <= 690 V AC <= 400 Hz
[Ie] rated operational current9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
20 A (at <140 °F (60 °C)) at <= 690 V AC AC-1 for power circuit
Control circuit typeAC 50/60 Hz
[Uc] control circuit voltage220...230 V AC 50/60 Hz
Motor power kW2.2 kW 220...230 V AC 50/60 Hz AC-3
4 kW 380...415 V AC 50/60 Hz AC-3
4 kW 440/690 V AC 50/60 Hz AC-3
2.2 kW 220...230 V AC 50/60 Hz AC-3e
4 kW 380...415 V AC 50/60 Hz AC-3e
4 kW 440/690 V AC 50/60 Hz AC-3e
2.2 kW 220...230 V AC 50/60 Hz AC-4
4 kW 380...415 V AC 50/60 Hz AC-4
4 kW 440/690 V AC 50/60 Hz AC-4
Auxiliary contact composition1 NO
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current20 A (at 140 °F (60 °C)) for power circuit
10 A (at 122 °F (50 °C)) for signalling circuit
Irms rated making capacity110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current90 A 122 °F (50 °C) - 1 s for power circuit
85 A 122 °F (50 °C) - 5 s for power circuit
80 A 122 °F (50 °C) - 10 s for power circuit
60 A 122 °F (50 °C) - 30 s for power circuit
45 A 122 °F (50 °C) - 1 min for power circuit
40 A 122 °F (50 °C) - 3 min for power circuit
20 A 122 °F (50 °C) - >= 15 min for power circuit
80 A - 1 s for signalling circuit
90 A - 500 ms for signalling circuit
110 A - 100 ms for signalling circuit
Associated fuse rating25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Insulation resistance> 10 MOhm for signalling circuit
Inrush power in VA30 VA (at 68 °F (20 °C))
Hold-in power consumption in VA4.5 VA (at 68 °F (20 °C))
Heat dissipation1.3 W
Control circuit voltage limitsOperational: 0.8...1.15 Uc (at <122 °F (50 °C))
Drop-out: >= 0.20 Uc (at <122 °F (50 °C))
Connections - terminalsscrew clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid
screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end
screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid
screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end
Maximum operating rate3600 cyc/h
Coil technologyWithout built-in suppressor module
Auxiliary contacts typeInstantaneous 1 NO
Signalling circuit frequency<= 400 Hz
Minimum switching current5 mA for signalling circuit
Minimum switching voltage17 V for signalling circuit
Operating time10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing
Safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Non overlap distance0.02 in (0.5 mm)
Mechanical durability10 Mcycles
Electrical durability1.3 Mcycles 9 A AC-3 <= 440 V
1.3 Mcycles 9 A AC-3e <= 440 V
0.16 Mcycles 20 A AC-1 <= 690 V
0.02 Mcycles 54 A AC-4 <= 440 V
Mechanical robustnessShocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27
Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27
Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27
Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6
Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Height2.3 in (58 mm)
Width1.8 in (45 mm)
Depth2.2 in (57 mm)
StandardsEN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
Product CertificationsCB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Protective treatmentTC IEC 60068
TC DIN 50016
Operating altitude6561.68 ft (2000 m) without derating
Flame retardanceV1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
CategoryUS10I1222326
Discount Schedule0I12
GTIN3389110363876
ReturnabilityYes
Country of originID
Unit Type of Package 1PCE
Nbr. of units in pkg.1
Package 1 Height2.598 in (6.600 cm)
Package 1 Width1.890 in (4.800 cm)
Package 1 Length2.441 in (6.200 cm)
Package weight(Lbs)6.208 oz (176.000 g)
Unit Type of Package 2S02
Number of Units in Package 250
Package 2 Height5.906 in (15.000 cm)
Package 2 Width11.811 in (30.000 cm)
Package 2 Length15.748 in (40.000 cm)
Package 2 Weight20.477 lb(US) (9.288 kg)
Unit Type of Package 3P06
Number of Units in Package 3400
Package 3 Height17.717 in (45.000 cm)
Package 3 Width23.622 in (60.000 cm)
Package 3 Length31.496 in (80.000 cm)
Package 3 Weight183.733 lb(US) (83.340 kg)
Warranty (in months)18

Specifications

Key Features

LC1K0910M7 is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 220V 50/60Hz AC coil and 1NO auxiliary contact. LC1K0910M7 is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 4kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it includes a 220V 50/60Hz AC coil and 1NO built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine). Very compact, 45mm wide, for DIN-rail and panel mounting. Provides a control circuit compatible with 50Hz and 60Hz supplies and 1NO built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).

What’s in the box

Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 220 to 230VAC coil

Specifications

  • SKU: SC692IP71XBEZNAFAMZ
  • Production Country: China
  • Size (L x W x H cm): Height 2.3 in (58 mm) Width 1.8 in (45 mm) Depth 2.2 in (57 mm)
  • Weight (kg): ~0.25 kg
  • Color: grey
  • Main Material: copper alloy

Verified Customer Feedback

Customers who have bought this product have not yet posted comments

Schneider  3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 220 to 230VAC coil Contactor, TeSys K

Schneider 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 220 to 230VAC coil Contactor, TeSys K

₦ 29,095
₦ 33,09512%
Questions about this product?

Recently Viewed

See All