product_image_name-Generic-XY-TR01 Digital Temperature Humidity Control Thermomete-1product_image_name-Generic-XY-TR01 Digital Temperature Humidity Control Thermomete-2product_image_name-Generic-XY-TR01 Digital Temperature Humidity Control Thermomete-3product_image_name-Generic-XY-TR01 Digital Temperature Humidity Control Thermomete-4product_image_name-Generic-XY-TR01 Digital Temperature Humidity Control Thermomete-5product_image_name-Generic-XY-TR01 Digital Temperature Humidity Control Thermomete-6product_image_name-Generic-XY-TR01 Digital Temperature Humidity Control Thermomete-7product_image_name-Generic-XY-TR01 Digital Temperature Humidity Control Thermomete-8

Share this product

Shipped from abroad

XY-TR01 Digital Temperature Humidity Control Thermomete

₦ 19,700
₦ 39,40050%

In stock

+ shipping from ₦ 4,198 to LEKKI-AJAH (SANGOTEDO)
0 out of 5
(No ratings available)

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees ₦ 4,198
Ready for pickup between 31 July and 04 August if you place your order within the next 23hrs 1mins

Door Delivery

Delivery Fees ₦ 5,158
Ready for delivery between 31 July and 04 August if you place your order within the next 23hrs 1mins

Return Policy

Free return within 7 days for ALL eligible itemsDetails

Seller Information

Technego

94%Seller Score

90 Followers

Follow

Seller Performance

Shipping speed: Good

Quality Score: Excellent

Customer Rating: Excellent

Product details



Features:





1.Product features are two main types of classification: the functions of temperature and humidity;





2.Function of temperature are as follows:





The automatic identification of work mode:





3.The system automatically according to the start/stop temperature, identify work mode;





Start temperature > stop temperature, cooling mode "C".





Start temperature < stop temperature, heating mode "H".





4.Cooling mode:





When the temperature≥Start temperature, relay conduction, red led on, refrigeration equipment begin to work;





When the temperature≤Stop temperature, relay disconnect, red led off, refrigeration equipment stop to work;








5.Heating mode:





When the temperature≤Start temperature,relay conduction, red led on,heating equipment begin to work;





When the temperature≥Stop temperature, relay disconnect, red led off, heating equipment stop to work;





6.Temperature correction function OFE (-10.0 ~ 10℃):





7.The system is working for a long time and may be biased, through this function correction, the actual temperature = measuring temperature + calibration value;














How to set up startup/Stop humidity:





1. In the running interface, long press"RH+"key3More than seconds, enter Starting humidity Set up the interface, the test can pass.RH+ RH-Key modifies parameters, waiting for parameters to be modified, waiting.6sAutomatically quit and save.





2. In the running interface, long press"RH-"key3More than seconds, enter Stop humidity Set up the interface, the test can pass.RH+ RH-Key modifies parameters, waiting for parameters to be modified, waiting.6sAutomatically quit and save.





Operation interface description:





 The working mode shows that when the temperature is started/Humidity and stopping temperature/After the humidity and other parameters are set, the temperature is/The current mode will be displayed synchronously in front of humidity"H/C","E/d");





Any relay is turned on, and the upper left corner of the interface is displayed"OUT"If the temperature relay is turned on, the temperature mode of the scintillation display is displayed."H/C"As a reminder, if the humidity relay is turned on, the humidity mode will be displayed"E/"As a reminder.





 





Other functions:





1. Parameter remote reading/Set up:





Can pass through UART Set the starting temperature./Humidity and stopping temperature/Humidity and temperature/Humidity correction and other parameters.





2. temperature/Humidity real-time report:





If the temperature is turned on/Humidity reporting function. 1sThe interval will detect temperature./Humidity and relay status UART It is transmitted to the terminal for data collection.





3. Relay enable(Default opening):





If the relay is turned off, the relay remains in a state of disconnection.





How to modify temperature/Correction of humidity:





1. In the running interface,Double click"TM+"key Enter the correction value setting interface, downlink display correction value type, uplink display specific value;OFE Temperature correction value RH Humidity correction value)





2. By passing short Click"TM"Key, toggle the parameters to be modified, through RH+ RH-Key, modify specific value; support long press short press;





3. When the parameters are modified,Double click"TM+"The key is to exit the correction value and set up the interface and save the data.





How to open it/Turn off relay enable switch:





In the running interface, short press"TM-"Key, open or close temperature Relay enable(on: open up OFF: shut down)After returning to the operating interface, if the temperature relay is in a closed state, the temperature symbol & lsquo; & rsquo; flashes to indicate a warning.





In the running interface, short press"RH-"Key, open or close humidity Relay enable(on: open up OFF: shut down)After returning to the running interface, if the humidity relay is turned off, the humidity symbol"%"flicker, as a reminder.





Serial port control(single chip microcomputer)TTL Level communication)





Communication standard:9600bps Data bit :8





Stop position :1





Checkout bit :none





flow control :none





Temperature and humidity data upload format description:





Temperature format:Working mode(H/C),Temperature value, temperature relay state;





Humidity format:Working mode(E/D),Humidity value, humidity relay status;





H,20.5Centigrade,CL :Heating mode, current temperature20.5The temperature relay is disconnected.








D,50.4%,OP:Dehumidification mode, current humidity50.4%The humidity relay is in the state of suction.














Specification:





Model:XY-TR01





Temperature range: -20~60℃





Humidity range: 00%-100%





Control probe: integrated sensor





Output type: relay output





Size: 57*60*20mm/2.2*2.4*0.8in





Weight: Approx.77g/2.7oz












Package list:





1 x Temperature and humidity Module

Specifications

Key Features

  • Product features are two main types of classification: the functions of temperature and humidity;
  • The automatic identification of work mode
  • Temperature correction function OFE (-10.0 ~ 10℃):
  • The system is working for a long time and may be biased, through this function correction, the actual temperature = measuring temperature + calibration value;
  • The system automatically according to the start/stop temperature, identify work mode

What’s in the box

0

Specifications

  • SKU: GE779IP88753YNAFAMZ
  • Model: N/A
  • Production Country: China
  • Size (L x W x H cm): 11×10×3
  • Weight (kg): 0.077
  • Color: N/A

Verified Customer Feedback

Customers who have bought this product have not yet posted comments

XY-TR01 Digital Temperature Humidity Control Thermomete

XY-TR01 Digital Temperature Humidity Control Thermomete

₦ 19,700
₦ 39,40050%
Questions about this product?

Recently Viewed

See All