Feature:
It is mainly used for measuring DC voltage, cur
rent, active power, frequency and energy consumption.
Comes with built in shunt, the current measure range is 0.01-10A.
Physical layer use UART to RS485 communication interface, baud rate is 9600, 8 data bits, 2 stop bit, no parity.
The application layer use the ModbusRTU protocol to communicate, it only supports function codes such as 0x03, 0x04,0x06, 0x41, 0x42, etc.
Voltage threshold can be set, divide into high v
oltage and low voltage threshold, when the measured voltage exceeds the threshold, it can alarm.
Specification:
Brand: PEACEFAIR
Model: PZEM-003
Voltage:
Measuring Rang
e: 0.05-300V (When the test voltage is <7V, please use the independent power supply mode)
Resolution: 0.01V
Measurement Accur
acy: 1%
Current:
Measuring Rang
e: 0.01-10A
Resolution: 0.01A
Measurement Accu
racy: 1%
Power:
Measuring
Range: 0.1-3kW
Resolution: 0.1W
Measurement
Accuracy: 1%
Energy Consumption:
Measuring Range: 0-9
999kWh
Resolution: 1Wh
Measurement Accuracy: 1
%
Reset Energy: Use Software to Reset
Over Voltage Alarm:
Default High Voltage Thresh
old: 300V
Default Low Voltage Threshold
: 7V
Communication Interface: RS485 Interface
Working Temperature: -20~60℃
Product Size: Approx. 9*6*2.3cm/3.5*2.4*0.9inch
Weight: Approx. 72g~92g / 2.5oz~3.2oz
Description
Resolution
Voltage value
1LSB correspond to 0.01V
Current value
1LSB correspond to 0.01A
Power value low 16 bits
1LSB correspond to 0.1W
Power value high 16 bits
Energy value low 16 bits
1LSB correspond to 1Wh
Energy value high 16 bits
High voltage alarm status
0xFFFF is alarm,0x0000 is not alarm
Low voltage alarm status
0xFFFF is alarm,0x0000 is not alarm
Register address
Description
Resolution
0x0000
High voltage alarm
threshold(5~350V),
default is 300V
1LSB correspond to 0.01V
0x0001
Low voltage alarm
threshold(1~350V),
default is 7V
1LSB correspond to 0.01V
0x0002
ModbusRTU address
The range is
0x0001~0x00F7
Optional
Kit
#1
1 x DC Consumption Meter
#2
1 x DC Consumption Meter
1 x RS485 to USB Cable
Note:
RS485 interface is passive ou
tput, need external connect 5V power supply and the external power supply should >100mA.
When the input test voltage is less than 7V, it must supply 5V independent work voltage through USB port.
Do NOT use the USB port bring b
y your PC to be the independent power supply, otherwise it may damage your PC.