HomeComputingComputersComputer ComponentsFans & CoolingDC-DC XL6009 Digital Boost Step Up Power Supply Module Adjustable 4.5-32V to 5-52V Step-up Voltage Regulator With LED Voltmeter
product_image_name-Generic-DC-DC XL6009 Digital Boost Step Up Power Supply Module Adjustable 4.5-32V to 5-52V Step-up Voltage Regulator With LED Voltmeter-1

Share this product

Shipped from abroad

DC-DC XL6009 Digital Boost Step Up Power Supply Module Adjustable 4.5-32V to 5-52V Step-up Voltage Regulator With LED Voltmeter

₦ 32,781
₦ 45,86429%

In stock

+ shipping from ₦ 6,487 to LEKKI-AJAH (SANGOTEDO)
0 out of 5
(No ratings available)
Variation available

Promotions

Delivery & Returns

Shipped from abroad 

Choose your location

Pickup Station

Delivery Fees ₦ 6,487
Ready for pickup between 21 May and 23 May if you place your order within the next 3hrs 41mins

Door Delivery

Delivery Fees ₦ 7,447
Ready for delivery between 21 May and 23 May if you place your order within the next 3hrs 41mins

Return Policy

Free return within 7 days for ALL eligible itemsDetails

Seller Information

Katlynne

1 Followers

Follow

Seller Performance

This seller does not have enough history for us to evaluate his performance yet

Product details

Product Features:
1.With Voltmeter Display, Voltmeter Error ±0.1V, Range 5~35V.(Note: Input Voltage Below 4.5V, Onboard Voltmeter Not Working Not Display)
2.Large Volume 5 * 5 Touch The on To Switch The Measurement Input Or Output Voltage, And There Is An Indicator Light To Show Which End Voltage Is Being Measured.The Default Digital Tube Displays The Input Voltage For The First Boot, And The Input Indicator IN Is On; Touch The on, Then The Digital Tube Displays The Output Voltage, And The Output Indicator Light OUT Is On.And And The Setting After Holding It, Even If It Is Powered Off And Then Powered On
3.The Voltmeter Can Be Turned Off, Press And Hold The Switch For More Than 1 Seconds And It Is Less Than 4 Seconds, Letting Go Can Be Turned Off.After The Voltmeter Is Turned Off, The Voltmeter Can Be Turned On As As The Switch Is Short Pressed.
4.The Input And Output Voltage Measurement Error Is More Accurate Function, Press And Hold The Switch For More Than 4 Seconds, And Then Enter The Voltage Measurement Error Is More Accurate Function After Letting Go. At This Time, The IN Light Is On (Calibrated The Input End), The Digital Tube Flashes To Display The Positive Value (The Factory Are 0.0), And At This Time, Short Press The on To Change This Value (The Value Range Is -0.5~0.5, The Unit Is V), The Positive Number Indicates The Upward Calibration,The Negatives Indicate Calibration Downwards.After Adjusting The Calibration Value Of The Input End, Press And Hold The on For More Than 2 Seconds, And Enter The Error Calibration Of The Output End After Letting Go, The OUT Light Is On (Calibration Of The Output End) At This Time, And The Calibration Value Of The Output End Is Displayed, The Adjustment Method And The Input End Are The Same, After The Calibration Value Of The Fixed Output End Is More Than 2 Seconds, Press And Hold The on For More Than 2 Seconds, Let Go And Save The Set Value And Return To The Normal Display Voltage, SetThe Correction Value Of The Corrected Value Immediately Takes Effect And Does Not Lose Power.(With This Function, You Can Meet Your Higher Precision Requirements)
5.With Terminal Block, It Can Also Be Used Easily Without Soldering Iron, And Retain The Wiring Point Of The Welding Wire
(The Input Voltage Must Be More Than 1v Higher Than The Voltage To Be Output)
6.The Output Current Can Be Up To 3A, It Is Recommended That The Working Current Be Around 2A, More Than 2A Plus Heat Sink
7.Using 400KHz Internal Oscillation Frequency, Bes To The Second Generation Switch Voltage Regulator, Small Power Consumption And High Efficiency
How To Use:
1.The Input And Output Voltage Measurement Error Is More Accurate: Press And Hold The Switch For More Than 4 Seconds, And Then Enter The Voltage Measurement Error Is More Accurate Function After Letting Go. At This Time, The IN Light Is On (Calibrated The Input End), And The Digital Tube Flashes To Display The Positive Value (The Factory Pimage


image


image

Specifications

Key Features

Product Features:
1.With Voltmeter Display, Voltmeter Error ±0.1V, Range 5~35V.(Note: Input Voltage Below 4.5V, Onboard Voltmeter Not Working Not Display)
2.Large Volume 5 * 5 Touch The on To Switch The Measurement Input Or Output Voltage, And There Is An Indicator Light To Show Which End Voltage Is Being Measured.The Default Digital Tube Displays The Input Voltage For The First Boot, And The Input Indicator IN Is On; Touch The on, Then The Digital Tube Displays The Output Voltage, And The Output Indicator Light OUT Is On.And And The Setting After Holding It, Even If It Is Powered Off And Then Powered On
3.The Voltmeter Can Be Turned Off, Press And Hold The Switch For More Than 1 Seconds And It Is Less Than 4 Seconds, Letting Go Can Be Turned Off.After The Voltmeter Is Turned Off, The Voltmeter Can Be Turned On As As The Switch Is Short Pressed.
4.The Input And Output Voltage Measurement Error Is More Accurate Function, Press And Hold The Switch For More Than 4 Seconds, And Then Enter The Voltage Measurement Error Is More Accurate Function After Letting Go. At This Time, The IN Light Is On (Calibrated The Input End), The Digital Tube Flashes To Display The Positive Value (The Factory Are 0.0), And At This Time, Short Press The on To Change This Value (The Value Range Is -0.5~0.5, The Unit Is V), The Positive Number Indicates The Upward Calibration,The Negatives Indicate Calibration Downwards.After Adjusting The Calibration Value Of The Input End, Press And Hold The on For More Than 2 Seconds, And Enter The Error Calibration Of The Output End After Letting Go, The OUT Light Is On (Calibration Of The Output End) At This Time, And The Calibration Value Of The Output End Is Displayed, The Adjustment Method And The Input End Are The Same, After The Calibration Value Of The Fixed Output End Is More Than 2 Seconds, Press And Hold The on For More Than 2 Seconds, Let Go And Save The Set Value And Return To The Normal Display Voltage, SetThe Correction Value Of The Corrected Value Immediately Takes Effect And Does Not Lose Power.(With This Function, You Can Meet Your Higher Precision Requirements)
5.With Terminal Block, It Can Also Be Used Easily Without Soldering Iron, And Retain The Wiring Point Of The Welding Wire
(The Input Voltage Must Be More Than 1v Higher Than The Voltage To Be Output)
6.The Output Current Can Be Up To 3A, It Is Recommended That The Working Current Be Around 2A, More Than 2A Plus Heat Sink
7.Using 400KHz Internal Oscillation Frequency, Bes To The Second Generation Switch Voltage Regulator, Small Power Consumption And High Efficiency
How To Use:
1.The Input And Output Voltage Measurement Error Is More Accurate: Press And Hold The Switch For More Than 4 Seconds, And Then Enter The Voltage Measurement Error Is More Accurate Function After Letting Go. At This Time, The IN Light Is On (Calibrated The Input End), And The Digital Tube Flashes To Display The Positive Value (The Factory P

What’s in the box

1x packages

Specifications

  • SKU: GE779EA6GIXIJNAFAMZ
  • Model: X-DNPJ-6-23-1290
  • Production Country: China
  • Size (L x W x H cm): 20x10x20
  • Weight (kg): 0.4
  • Color: Upgrade Version
  • Main Material: other

Verified Customer Feedback

Customers who have bought this product have not yet posted comments

DC-DC XL6009 Digital Boost Step Up Power Supply Module Adjustable 4.5-32V to 5-52V Step-up Voltage Regulator With LED Voltmeter

DC-DC XL6009 Digital Boost Step Up Power Supply Module Adjustable 4.5-32V to 5-52V Step-up Voltage Regulator With LED Voltmeter

₦ 32,781
₦ 45,86429%
Questions about this product?

Recently Viewed

See All