This website uses cookies
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
In stock
Shipped from abroad
Free return within 7 days for ALL eligible itemsDetails
Noarlall
88%Seller Score
26 Followers
Shipping speed: Good
Quality Score: Excellent
Product information download link
KG-FseriesUser Manual
http://68.168.132.244/KL-F_EN_manual.pdf
Android phone App link
http://68.168.132.244/app/KL/KL.apk
IOS mobile App link
Search Store for "KL Series"
Operation demonstration video
https://www.youtube.com/channel/UC2jIo4QgMdVootSBaIZNNlw/videos
Steps to connect the mobile phone APP to Bluetooth:
Open the mobile phone positioning;
Open the mobile phone Bluetooth;
Open the mobile phone APP, click search, and selectGxxx to automatically connect succefully;
No pairing paword is required, and no special pairing is required in the Bluetooth settings;
On April 1, 2022, Firmware update content:
Low -capacity reminder has been added to the mobile APP ;
Low temperature protection has been added to the mobile APP (relays are required for this function);
The temperature can be switched to display Fahrenheit or Celsius;
TheElectricity consumption (kW.h) only calculates the power consumed during charging;
Elapsed AHvalue (Ah) only calculates the capacity released during discharge;
The scale range of the voltage and current instrument panel in the mobile phone APP can be set freely, and the scale value of the voltage and current curve also changes accordingly;
The KL-F series volt-ampere meter is a new type of coulomb meter that can measure various physical such as voltage, current, power, charge and discharge capacity, watt-hours, and time. At the same time, it can also set to achieve over-voltage protection, under-voltage protection, Multiple protection functions such as over current protection, over power protection, and over temperature protection. The meter can automatically identify the direction of the current, and can monitor the battery capacity in real time, can view the measured data through Bluetooth, and can control the meter and firmware upgrade through the mobile phone APP.
►The product automatically recognizes and detects the current in both charging and discharging directions. When charging, the color of the current is green; when discharging, the color of the current is blue.
►Suitable for a variety of batteries: ternary lithium batteries, lead-acid batteries, lithium phosphate batteries, etc., as long as the battery is within the voltage measuring range.
►The shunt and screws are made of pure copper material, which has good electrical conductivity, low heat generation, and low power consumption. In the standby state, it will not consume too much battery power.
►Support Bluetooth connection mobile phone APP control, ar downloading and installing the APP, through the built-in Bluetooth connection, and all functions can be set through the mobile phone APP.
►The product can be set with over-voltage, under-voltage, over-current, over-power, and external over-temperature protection. When the value is out of the protection value range, the output state of the instrument is turned off (need to be used with a relay) to prevent damage to the electrical equipment. The protection recovery time and delay time can be set, which is suitable for various ocns.
►The product has added a self-calibration function, and the current and capacity values can still remain accurate ar long-time work.
►Amp-hour, watt-hour, and time data can be cleared during the measurement proce without affecting the measurement. The voltage and current values can also be fine-tuned to ensure accurate capacity.
►The product can be upgraded through the online firmware of the mobile phone, which increases the guarantee for the operation of the product.
►The product can accurately measure such as voltage, current, battery capacity, power, power consumption, ambient temperature, battery life, charging time, and batteryulative capacity.
Model
K L 110F
K L 140F
K L 160F
Sampling method
Shunt
Shunt
Shunt
Voltage measurement range(External power supply)
0- 120 V
0- 120 V
0- 120 V
Voltage measurement
range(Self-powered)
10-80V
10-80V
10-80V
Voltage resolution
0.01V
0.01V
0.01V
Current measurement range
0~100A
0~400A
0~600A
Current resolution
0.01A
0.1A
0.1A
Relay
optional
Temperature measurement range
-20-120℃
Capacity display range
0%~100%
Power measurement range
0~ 72 KW
Power resolution
0.01W
AHmeasurement range
0~9999.99AH
Capacityresolution
0.001AH
Watt-hour measurement range
0~9999.99kWH
Watt-hour accuracy
0.001WH
Time measurement range
0~999:59:59S
Timeresolution
1second
Bluetooth communication distance
10m
Voltageaccuracy
±2%+3characters
Currentaccuracy
±5%+10characters
Sampling rate
1 time /second
Measuring module
power consumption
About0.4W
Over power protection
0-99999.99W
Negative overcurrent protection
0~100A/400A/600A
Forward overcurrent protection
0~100A/400A/600A
Overvoltage protection
0~1 2 0V
Undervoltage protection
0~1 20 V
External over temperature protection
0-120℃
Protection recovery time
0-99s
Enter standby time
0-60s
Delay time setting
0-99S
Mailing addre
There are 99 P01-P99, P00 is the broadcast addre
The interface cool
function is powerful
to use mobile app,
can operate remotely,
support data recording
and export, convenient
and quick.
Mobile app supports
curve display, real-time
curve and history curve
of voltage and current,
and historical data
export.
►Over voltage, under voltage, over current, over power and external
over temperature protection can be set,When the value is not in the
range of protection value,the output state of the meter is turned off
(cooperation is required) The relay is used to prevent the electrical
equipment from being damaged.
►The protection recovery time and delay time can be set, which is
suitable for various ocns.
OVP
Over Voltage Protection
OTP
Over Temperature Protection
P
Low Voltage Protection
OPP
Over Power Protection
OCP
Over Current Protection
NCP
Negative Over Current Protection
1> Battery Monitor*1
4> Temperature r*1
2> Sampler*1
5> Terminal* 1
3>4P Connection Cable*1
6> 3P Connection Cable*1
Customers who have bought this product have not yet posted comments