Before, some customers didn't know the need to turn on the ZR function.
True four-wire 1Khz AC sinusoidal internal resistance meter 0.00001Ω---200Ω range. It can measure lead acid, lithium ion, lithium polymer, lithium phosphate, alkaline, dry battery, nickel hydrogen, nickel cadmium, on battery and so on. The ZR function is used to measure the internal resistance of 5 milliohms or le.
Note: Read the instructions and the instructions on the back of the instrument before use. It is forbidden to input AC signal and DC voltage higher than 100V.
The machine does not have a charger, charging can be charged with an Android phone charger~
The default length of the test line is 0.5 meters. If you need longer, please contact customer service to make up the difference.
Special combination: host + probe test line (suitable for measuring various types of batteries, good versatility. twisted pair of wires to improve anti-interference)
The main :
Internal resistance measurement:
Precision format: ± ([precision percentage] + [least significant digit]
Range minimum resolution accuracy
20mΩ 0.01mΩ 0.7%+7 (when ZR function is enabled)
200mΩ 0.1mΩ 0.5%+5
2Ω 1mΩ 0.5%+5
20Ω 10mΩ 0.5%+5
200Ω 0.1Ω 0.6%+5
In the range of 5%-95% of the gear position, if it is not within this range (le than 5% gear range range, or greater than 95% gear range range), the error may be greater than the above accuracy.
Voltage measurement:
Range Accuracy ± (% reading + % range)
1V 0.35+0.015
10V 0.30+0.010
100V 0.30+0.015
Positive and negative symmetry error ± (0.012% + 5 words)
Temperature drift within normal use temperature (10 ° C -40 ° C) 100ppm / ° C
9 Set to English Manual
Why the calibration and restore calibration options in the menu cannot be used, and what are the effects?
Answer: Calibration and recovery calibration is a factory mode that requires profeional equipment and instruments. Operate in accordance with the correct calibration method. It is not open to the outside world in order to avoid user misoperation. It does not affect the use of