This website uses cookies
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
This website uses cookies. For further information on how we use cookies you can read our Privacy and Cookie notice
Shipped from abroad
Free return within 7 days for ALL eligible itemsDetails
MOMONIYA
90%Seller Score
26 Followers
Shipping speed: Average
Quality Score: Excellent
Customer Rating: Excellent
4225
Wide voltage power supply6 ~ 30V
Interface is clear and simple, powerful, easy to understand, almost meet all the needs
There is a key stop function (STOPkey)With reverse polarity protection, reverse polarity does not burn
Increased sleep mode is enabled,5Minutes without any operation, automatically turn off the monitor any key wakeup
You can set differentOP,CL,LOP, which are independent of each other, were preserved
All setup automatically power-down save
Operating mode
Product Specifications
1:Operating Voltage:6--30V
2: Trier source: high level trier (3.0V-24V) Signal is not coplanar with systematically improved anti- capability (also common ground shorting self)
3: Output capability: to control DC30v5AOr exchange within220v5AWithin equipment
4 with optocoupler isolation, enhanced anti- capability, industriarade circuit board, to set of power forevermemory
pay attention:A paive contact relay output, the output is not charged, controls the action of a break-
Timing range
0.1S (small)~ 999Min (Large) continuously adjustable
How to choose the time range:
In the mode selection interfaceAr setting the parameter valuesdogSTOPkeySelect time range
. XXX decimal point in bits, time range:1second~ 999second
XX.X decimal point in ten, Timing range:0.1second99.9second
X.X.X. decimal point full brightne, Timing range:1minute~ 999minute
For example, you want to setOPYes3.2Seconds, then move the decimal point to the ten, digital display03.2
Parameter Description: OPOn-time,CLOff-time,LOPCycles(1-999Times,"---"Representatives infinite loop)
These are independent of each other, but each of these common mode , e.g.P1.1It is provided on-timeOPYes5Second user wants to switch toP1.2Mode, then enterP1.2When set the ,OPIt will be5second
In the main screen (Show000)dogSETon will be displayedOP(CL,LOP) And the corresponding timeXXX
If only modeOP(Eg modeP1.1,P1.2,P1.3) Time, then preSETKey will display onlyOPAnd the corresponding time
If the pattern hasOP,CL,LOP(Eg modeP3.1,P3.2) That PreSETKey displaysOPAnd the corresponding time,CLAnd the corresponding time,LOPAnd the corresponding number of
Ar setting mode, the main interface by preSETKey can easily view the current mode set, very convenient
How to set
1.First, determine the mode of operation of the relay
2.Depending on the mode of the relay, inMain interface(On power module will flash the current operating mode used (defaultP1.1Mode), then enterMain interface,) "PreSETkey2Ar the second release"enterMode selection interfaceBy short preUP,DOWNon to select the mode to be set (P1.1 ~ P-4)
3.Ar selecting a good mode to be set (for example,P3.2)dogSETkeySet the , the parameter to be set this time flashes (OPOn-time,CLOff-time,LOPCycles("---"Representatives infinite loop)), byUP,DOWNAdjustment parameter values, supports long pre (rapid increase or decrease) with a short pre (increase or decrease1Units); Ar setting the parameter values, bydogSTOPkeyDecimal point position is selected, selection time range (The appropriate time0.1second~ 999minute);dogSETThe parameter key, the current mode is set, the proce supra
4.Setting up the of the selected mode,PreSETkey2secondAr the release, currently set mode will blink at, and then return to the main screen, set the of succe is very simple
Main interface:Relay status display does not work. "000"(No decimal point), activated relays with a decimal point, the very clear
Mode selection interface:PreSETEnter, the setting is completed, preSETTo exit and return to the main interface
STOPKey Function extension
Relay enable mode
1.ON:OPRelays allow the on-time conduction
2.OFF: Relay prohibit conduction is always off
In the main interfacedogSTOPons, to realizeONwithOFFSwitching between the current state of which flashes and then return to the main screen. (This feature is an emergency stop function, a key opening-closing relay)
Sleep Mode:
C-PSleep mode: le than five minutes, without any operation, the LED display automatically shut down, the normal operation of the program
O-dNormal mode: LED is always on display
PreSTOPon2Ar the second release, achieveC-PwithO-dSwitching state, in which the current state of the flash, and then return to the main screen
Customers who have bought this product have not yet posted comments