Feature:
8 channels relay,each channel independently triggered independent delay, do not interfere with each other.
6 kinds of functional modes, each functional module has three sub-modes (no cycle, 2-99 cycle, always cycle).
Input optical isolation, Power anti-reverse diode.
High Q value SMD electrolytic capacitors, good responsiveness and low attenuation of signals in high frequency circuits
Parameter power-down save, relieved in use
Specification:
Working voltage: DC 12V
Maximum load :10A/250VAC,10A/125VAC,10A /30VDC, 10A/ 28VDC,10A/ 12VDC
Size:12*6.4cm/4.7*2.5in
Weight: Approx.132g/4.7oz
User Instructions:
Short press: press key time is less than 2 seconds;
Long press: press key time more than 2 seconds;
Status: working status , set status, power-saving status.
working status : start work after powering. Displays the
remaining time of 1 channel, the parameters can be displayed the
"channel select" to set;
Set status: short press the "SET" key to enter "channel
select" Status. Short press "OK" button to exit the setting;
power-saving status: in this Status,digital tubes donot
display,and other Feature work correctly. Long press "OK" button after 5
seconds to enter power-saving status, press again "OK" button for 5
seconds or re-power to exit power-saving status.
Factory settings: press and hold "++" and "--" two
button for 3 seconds, to restore factory settings, and the digital tube
will turn open . After re-power , will run default parameters.
Settings:
1.After power , the remaining time of digital display channel (default channel 1).
2.Press "SET" button to enter "channel select"
interface. In the "channel select" screen, then press "++"/"-" button to
select channel to operate (relay). Press "OK" button will exit "channel
select" screen, and save the current parameters. Press "SET" button
into "parameter settings" interface.
3. under "parameters" screen press "SET" button you can
switch parameters. "++"/"-" Button to modify the parameters. Press the
"OK" button to exit the "parameters" screen, and save the current
parameters
"channel select" interface
Bit1,2
Bit3
Bit4
(parameter)
Instructions
Ch
-
1
Channel 1parameters
Ch
-
2
Channel 2parameters
Ch
-
3
Channel 3parameters
Ch
-
4
Channel4parameters
Ch
-
5
Channel 5parameters
Ch
-
6
Channel 6parameters
Ch
-
7
Channel7parameters
Ch
-
8
Channel8parameters
parameter settings" interface:
Bit1
(parameter)
Bit2
parameter definition
Bit3 Bit4
default parameter
1
-
function mode(F)
F0-F5
F0
2
-
TimeT1: s
0-59s
4
3
-
TimeT1:min
0-59min
0
4
-
TimeT1:hour
0-99h
0
5
-
TimeT2:s
0-59s
4
6
-
TimeT2:min
0-59mins
0
7
-
TimeT2: hour
0-99h
0
8
-
Numbers of cycle Nx
0-99
1
Timer T1 T2 time minimum unit is second, so the timing range of T1 T2 is 99 hours 59 minutes 59 seconds.
The number of cycles(Nx) is the number of cycles to
perform an action triggered once(Nx = 00 indicates always cycle, Nx = 01
means no cycle).So you can set Number of cycles is: 1-99 times or
always cycle.
Noun resolved:
NO : Relay normally open contact
COM : Relay common contact
NC : Relay normally closed contact
Relay open :COM connect NO.
Relay close: COM disconnect NO.
Function Mode:
The following Function Modes can be set to cycle mode
operation.You can set Number of cycles (Nx 1~99 times,00 is always
cycle, the default is 01 not cycle).
F0: After power-up, the relay close. Trigger input (IN1/2/3/4), relay open. T1 time delay close.
F1: After power-up, the relay open. Trigger input , relay close. T1 time delay open.
F2: After power-up, the relay close. Trigger input ,
delay time T1 and relay open. T2 time delay relay close .
F3: After power-up, the relay open.Trigger input ,
delay time T1 and relay close. T2 time delay relay open .
F4: After power-up, the relay close. After the delay
time T1 and relay open. T2 time delay relay close.
F5: After power-up,the relay open. After the delay
time T1 and relay close . T2 time delay relay open.